Bryant 704D User Manual

704D  
SINGLE--PACKAGED ELECTRIC COOLING UNIT  
WITH PURON® (R--410A) REFRIGERANT  
User’s Information Manual  
A99338  
Fig. 1 -- Unit 704D  
NOTE TO EQUIPMENT OWNER:  
For your convenience, please record the model and serial numbers of your new equipment in the spaces  
provided. This information, along with the installation data and dealer contact information, will be helpful  
should your system require maintenance or service.  
UNIT INFORMATION  
INSTALLATION INFORMATION  
Model # _____________________________________  
Serial # ______________________________________  
Date Installed ________________________________  
DEALERSHIP CONTACT INFORMATION  
Company Name_______________________________  
Address______________________________________  
_____________________________________________  
Phone Number _______________________________  
Technician Name _____________________________  
_____________________________________________  
ACCESSORIES (List type and model #)  
_____________________________________________  
_____________________________________________  
_____________________________________________  
NOTE TO INSTALLER:  
This manual must be left with the equipment owner.  
1
Air Filters  
The air filter(s) should be checked every 3 or 4 weeks and changed  
or cleaned whenever it becomes dirty. Dirty filters produce exces-  
sive stress on the blower motor and can cause the motor to overheat  
and shut down.  
This unit must have air filters in place before it can be operated.  
These filters can be located in one of at least two places. In many ap-  
plications, the installer will provide return air filter grilles mounted  
on the wall or ceiling of the conditioned structure. In the instance of  
filter grilles, the filters can simply be removed from the grille and re-  
placed.  
ACCESS PANEL  
The other typical application is an accessory filter rack installed in-  
side the unit itself. The following information is given to assist in  
changing filters used in these internal filter racks.  
FILTER ACCESS  
PANEL*  
*For accessory filter rack.  
C99094  
Table 1 indicates the correct indoor filter size for your unit. Refer to  
Fig. 2 to access filters installed in the accessory filter rack. If using  
an Accessory Filter Rack refer to the Installation Instructions with  
it for correct filter sizes and quantities.  
Fig. 2 -- Accessory Filter Rack Access Panel  
(Optional Louvered Panels Shown)  
Fans and Fan Motors  
Table 1—Indoor Air Filter Data  
Periodically check the condition of fan wheels and housings and  
fan--motor shaft bearings. Contact your dealer for the required  
annual maintenance.  
Unit Size  
704D018---030  
704D036  
Filter Size  
Indoor and Outdoor Coils  
20x24x1 (508x610x25 mm)  
24x30x1 (610x762x25 mm)  
24x36x1 (610x914x25 mm)  
Cleaning of the coils should only be done by qualified service per-  
sonnel. Contact your dealer for the required annual maintenance.  
Condensate Drain  
704D042---060  
The drain pan and condensate drain line should be checked and  
cleaned at the same time the cooling coils are checked by your deal-  
er.  
To replace or inspect filters in accessory filter rack (See Fig. 2):  
1. Remove the filter access panel using a 5/16--in. nut driver.  
Compressor  
All compressors arefactory shippedwith anormal chargeof thecor-  
rect type of refrigeration grade oil. A compressor should rarely re-  
quire additional oil.  
2. Removethefilter(s)by pulling itoutoftheunit.If thefilter(s)  
is dirty, clean or replace with a new one.  
Condenser Fan  
When installing the new filter(s), note thedirection ofthe airflow ar-  
rows on the filter frame.  
!
WARNING  
If you have difficulty locating your air filter(s) or have questions  
concerning proper filter maintenance, contact your dealer for in-  
structions. When replacing filters, always use the same size and type  
of filter that was supplied originally by the installer.  
PERSONAL INJURY AND UNIT DAMAGE HAZARD  
Failure to follow this warning could result in personal injury,  
death or property damage.  
Do not poke sticks, screwdrivers, or any other object into  
revolving fan blades.  
The fan must be kept free of all obstructions to ensure proper cool-  
ing. Contact your dealer for any required service.  
!
WARNING  
Electrical Controls and Wiring  
FIRE AND UNIT OPERATION HAZARD  
Electrical controlsare difficultto checkwithout properinstrumenta-  
tion. If there are any discrepancies in the operating cycle, contact  
your local dealer and request service.  
Failure to follow this warning could result in personal injury,  
death or property damage.  
Never operate your unit without filters in place. An  
accumulation of dust and lint on internal parts of your unit can  
cause loss of efficiency.  
Refrigerant Circuit  
Therefrigerantcircuitisdifficulttocheckforleakswithout theprop-  
er equipment. If inadequate cooling is suspected, contact your local  
dealer for service.  
3
9. Inspection of compressor oil level by service person to  
ensure proper oil level is maintained in the compressor when  
it is installed and running.  
!
WARNING  
10. Operational check of the unit to determine working  
conditions.Repairoradjustmentshouldbe madeat thistime.  
EXPLOSION AND BURN HAZARD  
Failure to follow this warning could result in personal injury,  
death or property damage.  
Your servicing dealer may offer an economical service contract that  
covers seasonal inspections. Ask for further details.  
System under pressure. Relieve pressure and recover all  
refrigerant before system repair or final unit disposal. Use all  
service ports and open all flow--control devices, including  
solenoid valves.  
Complete service instructions can be found in the unit Installation,  
Start--up and Service Instructions.  
Warranty Certificate  
Unit Panels  
Your unit has a limited warranty. Be sure to read the warranty care-  
fully to determine the coverage for your unit.  
After performing any maintenance or service on the unit, be sure all  
panels are fastened securely in place to prevent rain from entering  
unit cabinet and to prevent disruption of the correct unit airflow pat-  
tern.  
Before you call for service...  
...check for several easily--solved problems.  
If insufficient heating or cooling is suspected:  
Regular Dealer Maintenance  
In addition to the type of routine maintenance you might be willing  
to perform, your unit should be inspected regularly by a properly  
trained service technician. An inspection (preferably each year, but  
at least every other year) should include the following:  
( ) Check for sufficient airflow. Check the air filter for dirt. Check  
for blocked return--air or supply--air grilles. Be sure they are open  
and unobstructed. If these checks do not reveal the cause, call your  
servicing dealer.  
1. Inspection and, if required, cleaning of the outdoor and  
indoor coils.  
If your unit is not operating at all, check the following list for  
easy solutions:  
2. Inspection and, if required, cleaning of the indoor coil drain  
pan.  
(
) Check to be sure that the temperature specified by your User  
Interface is set below the indoor temperature during the cooling sea-  
son or above the indoor temperature during heating season. Be sure  
the User Interface is set to COOL or HEAT and not OFF.  
3. Inspection and cleaning of blower wheelhousing andmotor.  
4. Inspection of all supply--air and return--air ducts for leaks,  
obstructions, and insulation integrity. Any problems found  
should be resolved at this time.  
(
) If your unit still fails to operate, call your servicing dealer for  
troubleshooting and repairs. Specify the model and serial numbers  
of your unit. (Record them in this manual in the space provided.) If  
the dealer knows exactly which unit you have, he may be able to  
offer suggestions over the phone, or save valuable time through  
knowledgeable preparation for the service call.  
5. Inspectionof theunit baseto ensurethat nocracks, gaps,etc.,  
exist which may cause a hazardous condition.  
6. Inspection of the unit casing for signs of deterioration.  
7. Inspection of all electrical wiring and components to assure  
proper connection.  
In Case of Trouble  
8. Inspection for leaks in the refrigerant circuit. Pressure check  
to determine appropriate refrigerant charge.  
If you perform the steps above and unit performance is still unsatis-  
factory, shut off the unit and call your dealer.  
Heating & Cooling Systems  
TO OBTAIN INFORMATION ON PARTS: Consult your installing dealer or classified section of your local telephone directory under the  
“Heating Equipment” or Air Conditioning Contractors & Systems” heading for dealer listing by brand name.  
Have available the Model No., Series Letter, & Serial No. of your equipment to ensure correct replacement part.  
Catalog No: OM01---80  
E2007 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46231  
Printed in the U.S.A.  
Edition Date: 03/07  
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.  
Replaces: New  
4

Brother HL 2280DW User Manual
Bryant 704B User Manual
Canon Pixma Mx922 Inkjet Multifunction Printer 6992B002 User Manual
Carrier 38CKC042 Air User Manual
Carrier 50DP User Manual
Carrier Y User Manual
Friedrich WY10B33A B User Manual
Haier Air Conditioner HPU 42CH03 User Manual
Haier Air Conditioner HW 24L1H User Manual
Honeywell 11280S User Manual