ARPF
Air HAndler
witH PAinted CAbinet
1½ to 5 tons
Multi-Position, three-sPeed
Standard Features
• Suitable for use with refrigerants R-410A and R-22
• Check flowrater expansion device
• Direct-drive, multi-speed motor
• Transformer and blower time-delay on all units
• Copper tube/aluminum fin coil
• Complies with the Factory-sealed Air Handling Credit
with or without field-installed filter kits as listed in
the 2001 Florida Building Code, Chapter 13, Section
610.2.A.2.1
• AHRI Certified
• ETL Listed
Cabinet Features
• Fully insulated, painted steel cabinet with attractive
Architectural Gray finish
• Built-in coil has horizontal, vertical, and downflow drain
pans with secondary drain connections
• Built-in filter rack for 1” filter (filter not included)
• Power supply entry at top; low-voltage entry on top and
both sides
• Factory-sealed to achieve 2% or less leakage rate with
or without field-installed filter kits at 1.0” water gauge
external duct static pressure
Contents
Nomenclature .......................................................................2
Product Specifications ..........................................................3
Dimensions ...........................................................................4
Airflow Data ..........................................................................5
Heat Kit Match-Ups ...............................................................6
Wiring Diagram .....................................................................7
Accessories ............................................................................8
the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installa-
tion. Online registration is not required in California or Québec.
SS-GARPF
5/11
Supersedes 1/11
ProduCt SPeCifiCAtionS
SPeCifiCAtionS
ARPF
182416*
ARPF
193116*
ARPF
303016*
ARPF
363616*
Nominal Ratings
Cooling (Btu/h)
CFM (High/ Med/ Low)
Blower
18,000 - 24,000
1,025/ 790/ 570
18,000 - 30,000
1,025/ 780/ 545
30,000
36,000
1,330/ 1,230/ 980
1,230/ 1,140/ 955
Diameter
9½"
6"
9½"
6"
9½"
8"
9½"
6"
Width
Coil Drain Connect FPT
Service Valve
¾"
¾"
¾"
¾"
Liquid Line
⅜"
⅜"
⅞"
⅜"
⅜"
Sucꢀon Line
¾"
¾"
¾"
Electrical Data
Voltage
208/240
2.1/2.1
15 / 15
197/ 253
1.7/ ⅓
208/240
1.9/1.9
15 / 15
197/ 253
1.48/ ¼
155
208/240
3.3/3.3
15 / 15
197/ 253
2.64/ ⅓
144
208/240
3.3/3.3
15/15
Min Circuit Ampacity
Max. Overcurrent Device (amps)
Min./ Max VAC
Blower Motor FLA/ HP
Ship Weight (lbs)
197/ 253
2.64/ ⅓
164
116
ARPF
364216*
ARPF
374316*
ARPF
486016*
ARPF
496116*
Nominal Ratings
Cooling (Btu/h)
CFM (High/ Med/ Low)
Blower
36,000 - 42,000
36,000 - 42,000
48,000 - 60,000
48,000 - 60,000
1625 / 1400 / 1250
1,925/ 1,550/ 1,345
1,985/ 1,875/ 1,650
1,915/ 1,795/ 1,585
Diameter
10⅝"
8"
11 15/16"
10 ¹/16"
¾"
10⅝"
10⅝"
¾"
10⅝"
10⅝"
¾"
Width
Coil Drain Connect FPT
Service Valve
¾"
Liquid Line
⅜"
⅞"
⅜"
⅞"
⅜"
⅞"
⅜"
⅞"
Sucꢀon Line
Electrical Data
Voltage
208/240
3.7/3.7
15 / 15
197/ 253
2.95/ ½
160
208/240
4.2/4.2
15 / 15
197/ 253
3.39/ ½
195
208/240
5.4/5.4
15 / 15
197/ 253
4.3/ ¾
208/240
5.4/5.4
15/15
Min Circuit Ampacity
Max. Overcurrent Device (amps)
Min./ Max VAC
Blower Motor FLA/ HP
Ship Weight (lbs)
197/ 253
4.3/ ¾
192
183
SS-GARPF
3
Product SPecificationS
dimenSionS
Model
A
B
C
D
E
F
G
H
I
J
ARPF182416*
ARPF193116*
ARPF303016*
ARPF363616*
ARPF364216*
ARPF374316*
ARPF486016*
ARPF496116*
42⅛”
46¾”
46¾”
46¾”
53¼”
53¼”
53¼”
53¼”
22”
22”
22”
22”
24”
24”
24”
24”
13½”
17½”
17½”
17½”
20”
15½”
19½”
19½”
19½”
22”
10”
10”
10”
10”
12”
12”
12”
12”
14½”
14½”
14½”
14½”
14½”
14½”
14½”
14½”
11¹⁵/₁₆”
11¹⁵/₁₆”
11¹⁵/₁₆”
11¹⁵/₁₆”
11¹⁵/₁₆”
11¹⁵/₁₆”
11¹⁵/₁₆”
11¹⁵/₁₆”
13⅛”
17⅛”
17⅛”
17⅛”
19⅝
19⅝
19⅝
19⅝
17¹⁵/₁₆”
17¹⁵/₁₆”
17¹⁵/₁₆”
17¹⁵/₁₆”
19¹⁵/₁₆”
19¹⁵/₁₆”
19¹⁵/₁₆”
19¹⁵/₁₆”
2”
2”
2”
14/5”
14/5”
14/5”
14/5”
14/5”
20”
22”
20”
22”
20”
22”
4
SS-GARPF
ProduCt SPeCifiCAtionS
Airflow dAtA
Model
CFM delivered against External Static Pressure
Speed
0.1"
0.2"
0.3"
0.4"
0.5"
High
Med.
Low
1,155
940
1,090
890
1,025
860
950
815
895
755
ARPF182416*
695
665
650
610
550
High
Med.
Low
1,135
860
1,085
825
1,025
780
965
915
ARPF193116*
ARPF303016*
ARPF363616*
ARPF364216*
ARPF374316*
ARPF486016*
ARPF496116*
750
680
600
570
545
500
465
High
Med.
Low
1,385
1,340
1,075
1,310
1,270
1,045
1,700
1,500
1,370
2,065
1,685
1,490
2,150
1,940
1,610
2,150
1,960
1,670
1,315
1,290
1,030
1,240
1,210
1,005
1,660
1,440
1,300
2,000
1,635
1,425
2,120
1,930
1,600
2,105
1,935
1,625
1,240
1,230
980
1,155
1,140
910
1,065
1,050
840
High
Med
Low
1,155
1,140
955
1,090
1,075
885
1,020
980
805
High
Med.
Low
1,625
1,400
1,250
1,925
1,550
1,345
2,070
1,905
1,590
2,040
1,895
1,585
1,545
1,350
1,230
1,860
1,470
1,280
2,000
1,860
1,575
1,970
1,825
1,525
1,505
1,345
1,220
1,780
1,410
1,205
1,940
1,790
1,550
1,880
1,750
1,455
High
Med.
Low
High
Med.
Low
High
Med.
Low
Note: Assumes dry coil with filter in place; SCFM correcꢀon for wet coil = 4% (208V / 240V
SS-GARPF
5
ProduCt SPeCifiCAtionS
HeAt Kit mAtCH-uPS
ARPF
182416
ARPF
193116
ARPF
303016
ARPF
363616
ARPF
364216
ARPF
374316
ARPF
486016
ARPF
496116*
Heat Kits
HKR-03*
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
HKR-05*, HKR-05C*
HKR-06*
X
X
X
X
X
X
HKR-08*, HKR-08C*
HKR-10*, HKR-10C*
HKR-15C*
X1
X1
X2
X1
X1
X2
X
X
X
X
X1
X2
X2
X2
X2
X2
X
X2
X
X
X3
X3
X3
X3
X3
X3
X3
X3
X3
X3
HKR-20C*
HKR-21C*
^ HKR3-15*
X2
^ HKR3-20*
*
C
^
Revision level that may or may not be designated
Circuit breaker opꢀon
Heat kit requires three-phase power supply
¹
²
³
Air handler must either be on medium or high speed
Air handler must be on high speed
For staꢀc pressure of 0.6 or higher, air handler must be on medium
or high speed
Single Point Kit **
Model
SPW-01
HKR-15C HKR-20C HKR-21C
X
X
X
** Must be installed along with any of the above
compaꢀble heat kits. This kit will fit any ARPF air
handler as long as a compaꢀble heat kit is installed
in the unit.
6
SS-GARPF
ProduCt SPeCifiCAtionS
wiring diAgrAm
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
⚡
⚠ WARning
SS-GARPF
7
ProduCt SPeCifiCAtionS
ACCeSSorieS
exPAnSion VAlVe KitS for Air Conditioning And HeAt PumP APPliCAtionS
Tonnage:
Outdoor Unit
Kit Number
XVB18-36C
Description
Application
Refrigerant
20% Bleed Valve
20% Bleed Valve
Non-bleed Valve
Non-bleed Valve
Non-bleed Valve
Non-bleed Valve
Non-bleed Valve
Non-bleed Valve
Non-bleed Valve
Non-bleed Valve
AC Only
AC Only
AC Only
AC Only
AC or HP
AC or HP
AC or HP
AC or HP
AC or HP
AC or HP
R-22
R-22
1½ - 3 Ton
3½ - 5 Ton
1½ - 3 Ton
3½ - 5 Ton
1½ - 2 Ton
2½ - 3 Ton
3½ - 5 Ton
1½ - 2 Ton
2½ - 3 Ton
3½ - 5 Ton
XVB42-60C
XV18-36C
XV42-60C
TX2N2
R-22
R-22
R-22
TX3N2
R-22
TX5N2
R-22
TX2N4
R-410A
R-410A
R-410A
TX3N4
TX5N4
drAin PAn inSulAtion KitS
downflow APPliCAtionS
HorizontAl APPliCAtionS
Chassis Size
Small (15½”)
Medium (19½”)
Large (22”)
Insulation Kit
Chassis Size
Small (15½”)
Medium (19½”)
Large (22”)
Insulation Kit
DPI18-30/20
DPI36-42/20
DPI48-60/20
DPIH18-32
DPIH36-42
DPIH48-61
Note: Each kit contains enough material to modify 20 coils
filterS
Qty
Filter #
Required
1824
FIL 18-32
FIL-36-42
FIL-36-42
FIL 48-61
FIL 48-61
FIL 48-61
1
1
1
1
1
1
1931
3030/ 3636
3642
3743
4860/4961
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without
notice or without incurring obligations. © 2010 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
8
SS-GARPF
|