Energizer PP355 User Manual

Energizer  
Zinc Air Prismatic  
Handbook  
Including performance and design data for the PP355  
P a g e | 3  
Section 1: Battery Overview  
For over 35 years, Energizer has manufactured miniature Zinc Air batteries primarily designed to provide  
power to miniature hearing aids. Zinc Air chemistry provides the highest available energy density  
compared to other commercially available batteries. Energizer Zinc Air Prismatic batteries employ  
technology similar to what is used in hearing aid batteries, but with a thin prismatic form factor  
providing power for a broad range of applications.  
1.1 ‐‐ Zinc Air Chemistry  
Zinc Air batteries are based on the alkaline chemistry (Zn/MnO2) used in standard AA and AAA primary  
batteries. The high energy density of Zinc Air results from replacing the manganese dioxide (MnO2)  
cathode with a thin air electrode. This air electrode contains carbon which catalyzes oxygen to allow it  
to react with zinc. The thin air electrode eliminates the need to contain both reactants in the battery, so  
the majority of the battery can be filled by the zinc anode. As a result Zinc Air provides the highest  
available energy density compared to commercially available batteries.  
The typical open circuit voltage (OCV) of Zinc Air is 1.4 V. Under load, the operating voltage is generally  
between 1.10 and 1.30 volts. The half cell and overall reactions for a Zinc Air battery are as follows:  
Anode:  
2Zn + 4OH2ZnO + 2H2O + 4e‐  
O2 + 2H2O + 4e4OH‐  
2Zn + O2 2ZnO  
Cathode:  
Overall:  
1.2 ‐‐ Construction  
Air holes are designed into the battery container to allow oxygen to flow into the battery. Because  
exposure to the environment can degrade battery performance over time, the air holes are sealed by a  
tab prior to consumer use. The tab must be removed before the battery is placed into a device. Once  
air enters the holes, it flows through an air distribution layer. This layer helps to distribute air across the  
entire air electrode. Figure 1 shows a cross section of an Energizer Zinc Air prismatic battery.  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  
P a g e | 4  
Figure 1: Cross Section View of Zinc Air Prismatic Battery  
Energizer Zinc Air Prismatic batteries are designed to allow air to enter the air holes and to prevent the  
transport of liquid electrolyte out of the battery. A gasket is used to seal between the anode cup and  
the cathode can. The gasket also electrically insulates the negative cup from the positive can. An air  
electrode and a loose layer of Teflon are compressed onto a band of sealant on the bottom of the can.  
This Teflon layer allows gasses to enter the battery while preventing liquid from passing through.  
1.3 ‐‐ Features of Zinc Air Prismatic  
Energizer’s Zinc Air Prismatic batteries offer a 5 mm thin, prismatic construction designed to work with a  
variety of applications. This shape is consistent with the low profile design of today’s devices, often  
requiring a thinner battery solution. The thinnest round cell available is the AAAA battery at  
approximately 8 mm, and many Lithium Ion rechargeable solutions have a thickness of 5 mm.  
Energizer Zinc Air Prismatic batteries also offer the opportunity to significantly lower manufacturer  
costs. It is likely that the cost of a Zinc Air Prismatic battery solution will be less than the cost of a  
Lithium Ion battery. Adding to the cost of a Lithium Ion solution is the cost of circuitry for charge and  
discharge control, which is not needed with Zinc Air Prismatic batteries. Furthermore Zinc Air Prismatic  
batteries are ready to be used out of the package. There is no need for charge adaptors.  
Energizer Zinc Air Prismatic batteries can last up to 3X longer than comparable volume battery systems.  
This service advantage is due to Zinc Air technology offering the highest energy density for non‐  
rechargeable and rechargeable consumer batteries. Figure 2 demonstrates this advantage over Alkaline  
and Lithium Ion batteries of similar volume.  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  
P a g e | 5  
Figure 2: Runtime for Equivalent Volume AAAA Batteries in 50 mW Devices  
50  
40  
30  
38  
14  
12  
20  
10  
0
AAAA Alkaline  
Lithium Ion  
ZAP PP355  
The high energy density of Zinc Air is made possible by using a thin air electrode where the cathode  
reaction takes place and by using atmospheric oxygen as the cathode reactant. The result is greater  
internal volume for zinc, the active anode material. More zinc translates into longer runtime in similar  
overall volume. Figure 3 demonstrates the higher energy density of Zinc Air compared to other  
consumer battery systems. The chart on the left displays volumetric energy density in units of Wh/L,  
and the chart on the right shows gravimetric energy density in units of Wh/kg. This data is based on the  
volume of a AA sized battery for all systems and a continuous 50mA current drain to a 0.9 volt cutoff.  
Figure 3: Comparison of Zinc Air versus Other Battery Technologies  
1000  
900  
800  
700  
600  
500  
400  
300  
200  
100  
0
400  
350  
300  
250  
200  
150  
100  
50  
890  
345  
307  
565  
218  
522  
450  
171  
396  
153  
151  
371  
343  
95  
87  
156  
0
Carbon  
Zinc  
Alkaline  
Lithium  
Li Ion Lithium Ion Lithium  
Polymer MnO2  
NiMH  
Zinc  
Air  
Carbon  
Zinc  
Alkaline  
Lithium  
Li Ion Lithium Ion Lithium  
Polymer MnO2  
NiMH  
Zinc  
Air  
Energizer Zinc Air Prismatic batteries have an operating voltage similar to Alkaline, which is between  
1.10 and 1.30 volts depending on the drain rate of the device. The discharge profile however is  
relatively flat similar to rechargeable Nickel Metal Hydride batteries. Figure 4 contains examples of  
discharge curves for Zinc Air, Alkaline, Nickel Metal Hydride, and Lithium Iron Disulfide batteries. Even  
though the Zinc Air PP355 battery has the same external volume as the AAAA battery, it delivers up to  
3X the runtime at a 50 mW discharge.  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  
P a g e | 6  
Figure 4: Comparison of Discharge Curves at 50 mW Continuous  
1.6  
1.4  
1.2  
1.0  
0.8  
0.6  
0.4  
NiMH  
AAA  
Zinc Air  
PP355  
Alkaline  
AAA  
Alkaline  
AAAA  
Lithium  
AAA  
0
5
10  
15  
20  
25  
30  
35  
40  
45  
Discharge Time (hrs)  
The impedance of Energizer Zinc Air Prismatic batteries is higher than similar volume Alkaline batteries,  
and it decreases slightly through the life of the battery. The impedance should not impact battery  
performance at low to moderate discharge rates. At higher rate discharges, this higher impedance will  
reduce operating voltage and delivered energy.  
1.4 ‐‐ Zinc Air Prismatic Battery Sizes  
Energizer Zinc Air Prismatic batteries provide an ideal form factor for devices with a thin profile. The  
family of battery sizes is shown in Figure 5, ranging from AAA Alkaline volume equivalent to ½ the AAAA  
Alkaline volume equivalent. Energizer Zinc Air Prismatic battery nomenclature is determined by the IEC  
standard. The first ‘P’ indicates Zinc Air chemistry, the second ‘P’ indicates the prismatic form factor,  
the first two digits represent the diagonal in mm, and the last digit is the battery height in mm. For  
example the PP355 has a 35 mm diagonal distance and a height of 5 mm.  
Figure 5: Zinc Air Prismatic Battery Sizes  
PP425  
36.0  
22.0  
5.0  
PP355  
32.2  
14.7  
5.0  
PP255  
22.6  
10.3  
5.0  
Length (mm)  
Width (mm)  
Thickness (mm)  
Volume (cm3)  
Cell Weight (g)  
3.96  
11.7  
2.37  
6.8  
1.16  
3.4  
Continuous Rate Capability  
Capacity Rated (mAh)  
< 200 mW < 100 mW < 50 mW  
3600 1800 720  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  
P a g e | 7  
Section 2: PP355 Performance Characteristics  
This section describes the performance of the PP355 battery. Standard discharge curves, performance  
at a variety of environmental conditions, pulse capability, and service maintenance data are presented.  
2.1 ‐‐ Performance at Standard Conditions  
Standard conditions for Energizer Zinc Air Prismatic batteries are defined as 21°C and 50% relative  
humidity (RH). Under these conditions, the PP355 battery is designed to provide continuous discharge  
capability up to 100 mW. While best performance is obtained in standard conditions and continuous  
duty cycles, Energizer Zinc Air Prismatic Batteries perform well over a wide range of environmental  
conditions and in intermittent applications as well. Figure 6 contains typical discharge curves for the  
PP355 under standard conditions and constant power loads of 25, 50, 75, and 100 mW.  
Figure 6: PP355 Discharge Curves at Continuous Constant Power  
1.4  
1.3  
25 mW  
1.2  
50 mW  
75 mW  
1.1  
100 mW  
1.0  
0.9  
0.8  
0
500  
1000  
1500  
2000  
2500  
Discharge Energy (mWh)  
Energizer Zinc Air Prismatic batteries significantly outperform existing Alkaline cylindrical solutions of  
equivalent volume. To demonstrate this advantage, Figure 7 shows how PP355 and AAAA Alkaline  
batteries perform on the same continuous power tests. The PP355 lasts longer than the alkaline AAAA  
even though the volumes of both battery types are approximately the same at 2.37 cc and 2.2 cc,  
respectively.  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  
P a g e | 8  
Figure 7: Comparison of Performance under Continuous Constant Power  
Continuous Discharge Time (hrs)  
AAAA  
24  
11  
6
PP355  
88  
25 mW  
50 mW  
75 mW  
100 mW  
38  
24  
4
15  
2.2 ‐‐ Performance at Other Environmental Conditions  
When a Zinc Air battery is exposed to a nonstandard environment, a driving force for water transport in  
or out of the battery exists. Movement of water vapor into the battery can fill void space in the anode  
cavity under high humidity environments, and movement of water vapor out of the battery can dry out  
the electrolyte in low humidity environments. Either situation can decrease battery performance over  
time.  
Understanding the environmental conditions that a battery might encounter is critical to estimating  
battery performance. A study was done at Energizer to determine realistic extreme conditions for  
battery testing, using climate data from 61 cities across the globe. These cities represent the major  
markets for both devices and batteries. Combinations of daily morning and afternoon temperature and  
humidity were compiled and analyzed to determine reasonable temperature and humidity extremes.  
Hot and Humid Conditions:  
Zinc Air Prismatic batteries can take on water when exposed to hot and humid conditions. This can limit  
battery performance by taking up void volume in the air electrode and anode compartment. At 35°C  
and 75% RH conditions, there is a driving force for water gain larger than 99% of conditions seen in  
combined indoor and outdoor data from the top 61 cities globally. Service tests with the PP355 under  
these conditions show very good service even at 1 hr per day intermittency.  
Hot and Arid Conditions:  
Zinc Air Prismatic batteries can lose water when exposed to hot and arid conditions which can limit  
battery performance by drying out the battery. Under 35°C and 25% RH conditions, there is a driving  
force for water loss larger than 99% of conditions seen in combined indoor and outdoor data from the  
top 61 cities globally. Service testing with the PP355 at these conditions shows very good service even  
at 1 hr per day intermittency.  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  
P a g e | 9  
Lower Temperature Conditions:  
Air holds less moisture as temperature decreases, and the difference between low and high relative  
humidity becomes less significant. At 0°C, the difference between the humidity of the PP355 and the  
environment is negligible. While the service obtained from a PP355 at temperatures lower than  
standard conditions is less, the loss is similar to Alkaline batteries. In general the “up to 3X” service  
advantage for Zinc Air batteries over Alkaline batteries is maintained.  
Figure 9: Service Summary for Zinc Air Prismatic Batteries at Various Environmental Conditions  
Humid  
Typical  
Arid  
Cold  
(35°C / 75% RH)  
(21°C / 50% RH)  
(35°C / 25% RH)  
(0°C)  
50 mW  
45 hrs  
38 hrs  
40 hrs  
12 hrs  
Continuous  
(2 days)  
(2 days)  
(2 days)  
(0.5 days)  
50 mW  
38 hrs  
36 hrs  
30 hrs  
16 hrs  
1h per 12hr  
(19 days)  
(18 days)  
(15 days)  
(8 days)  
50 mW  
1h per 24hr  
25 hrs  
(25 days)  
30 hrs  
(30 days)  
17 hrs  
(17 days)  
-
generally about 12 hrs (0.5 days)  
for these temperatures and all intermittencies  
5 hrs  
(0.25 days)  
50 mW  
Each battery was exposed to the specified conditions for the entire test duration.  
Figure 9 demonstrates the service obtained from a PP355 battery at 35°C/75% RH, 35°C/25% RH, and  
0°C conditions. The data presented with units of hours represent the runtime that the battery  
delivered, while the values in parentheses indicate the duration of the test in days. In summary, the  
PP355 battery sustains a significant performance advantage over similar volume Alkaline batteries with  
varying intermittency in extreme temperature and humidity conditions.  
2.3 ‐‐ Pulse Capability  
The pulse capability of Zinc Air batteries is dependent on the instantaneous amount of oxygen available  
at the air electrode at a given time. While the PP355 battery can continuously discharge at rates up to  
100 mA, the battery can provide significantly more current in short bursts. Figure 8 demonstrates that a  
fresh PP355 battery can provide pulses of up to 1500 mA, depending on the duration of the pulse. The  
pulse capability of a Zinc Air battery can also be affected by the frequency of the pulses. Pulse capability  
will drop over time without sufficient time for more oxygen to enter the air electrode.  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  
P a g e | 10  
Figure 8: Pulse Capability of PP355 Batteries  
1
1.1VCutoff  
1.0VCutoff  
0.9VCutoff  
0.8VCutoff  
0.1  
0.01  
0.001  
0.0001  
0
200  
400  
600  
800  
1000  
1200  
1400  
1600  
Current(mA)  
2.4 ‐‐ Service Maintenance  
Zinc Air batteries are stored with adhesive backed tabs prior to use. These tabs seal the air holes against  
oxygen and water ingress. To obtain the full battery performance, the tab should be removed only  
immediately prior to use. When the battery is sealed by the tab, service loss due to self discharge is  
approximately 5% per year. Figure 10 illustrates the rates at which capacity is lost with the tab on and  
the tab removed.  
Figure 10: Service Maintenance of Energizer Zinc Air Prismatic Batteries  
100%  
95%  
sealed  
(on tab)  
90%  
unsealed  
(tab removed)  
85%  
80%  
0
1
2
3
4
Shelf Life (yr)  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  
P a g e | 11  
2.5 ‐‐ Activation Time and Air Requirements  
When batteries are stored with the adhesive tab intact, they have a lower open circuit voltage (OCV)  
since the oxygen contained in the battery is consumed during storage. When the tab is removed the  
OCV will rise as oxygen activates the air electrode. With multiple air holes for added rate capability, the  
PP355 may take a couple of seconds to air up enough to sustain a 50 mW load above 1 volt. Based on  
the time it will take a consumer to remove the tab, insert the battery into the device, close the battery  
compartment, the battery should be ready to support the device load when the user turns on the  
power.  
For maximum performance of a PP355 under a 50 mW continuous load, a minimum air flow rate of 23  
cc of air per minute is needed. For higher power demand devices (100 mW), a minimum of 46 cc of air  
per minute is needed. In most devices this amount of air easily leaks into the battery compartment.  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  
P a g e | 12  
Section 3: Application and Design Considerations  
Excessive exposure to air can have an adverse affect on Zinc Air battery operation, primarily due to  
carbon dioxide reacting with the electrolyte in the air electrode. The battery can also absorb water or  
dry out depending on ambient conditions. Balancing the air requirement of the battery during discharge  
versus the need to minimize exposure during rest is called air management. Air management might be  
as simple as removing the tab from the battery and inserting it into a device, or it might include a system  
to open and control air access to the battery as needed. Air management is application specific, and  
most devices will require some degree of air management to optimize battery performance.  
3.1 ‐‐ Air Management  
There are several types of air management. The simplest method of air management is removing the  
tab and putting the battery in the device. This is how miniature zinc air cells are used in hearing aids  
since the total battery life is typically expected to be 68 weeks. As the device usage becomes more  
intermittent, other methods of air management are needed to deliver optimal battery performance.  
Throttling is a technique to permanently restrict air access to only what is needed by the battery in a  
specific application. Throttling is most appropriate in devices that require a small portion of the  
maximum current that a battery can sustain. For example, a device might require 10 mA of current  
compared to the maximum of 100 mA that a PP355 can sustain. This technique works best for devices  
that have a low average drain rate with little increased power needs. By restricting the air access to the  
battery, the performance life can be extended.  
As device use becomes more intermittent and as device power demands increase, valved (open and  
shut) air management becomes more appropriate. Valved systems are either mechanical or electronic.  
Each system requires a sealed battery or battery compartment, into which air is introduced by the valve  
when the device needs power. A seal can be accomplished with common materials such as orings,  
gaskets, overmolded or twopart injection molded materials, or other methods. A mechanical solution  
might be an ON / OFF slide switch which acts as a simple air valve. Other device specific mechanical  
actions could also be used to open and close the air access. Examples include changing device settings,  
moving a piece or a part of the device during use, pressing a button, turning a dial, or manipulating a  
threaded component. An electronic valve would act in a similar fashion, except that the device  
electronics would open the air access automatically. A valve could be opened as a function of device  
state (on = open, off = closed), or it might be a function of the instantaneous power needs of the device.  
In a valved air management solution, a low level of air access might still be needed to be able to provide  
the quiescent, or background, power required to activate the ON/OFF valve. Figure 11 shows generally  
where each of these air management techniques is appropriate.  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  
P a g e | 13  
Figure 11: Overview of Different Air Management Techniques  
high  
high degree of air management needed,  
none or small  
degree of air  
management  
needed, since cell  
capacity is quickly  
used  
cell has high air access but is expected to  
be in service with long periods of “off”  
time (>3 months)  
(13 months)  
throttling needed to  
maximizeservice  
time (>3 months)  
low  
continuous  
intermittent  
Duty Cycle  
3.2 ‐‐ Elements of Air Management  
Two elements of a successful indevice air management system are a means for allowing controlled air  
access to the battery and an air plenum for even air distribution. An air plenum is an air gap, or volume,  
which has access to all of the air holes on the battery. The air plenum allows for more even air  
distribution over the battery air holes, and it provides a reserve of air immediately available to the  
battery to handle peak power needs. Controlling air access to the battery is accomplished by creating an  
access path to the sealed volume of air within a device. The air access path is designed to allow a  
desired amount of air to flow to the sealed volume of air, which includes the plenum, either  
continuously or intermittently. A sealed volume of air can be created by sealing an entire device, a  
portion of the device including the battery compartment, or just a plenum above the air hole side of the  
battery. The power requirements of the device determine the rate at which air is required to flow to the  
battery.  
Figure 12 illustrates a simple, cost effective air management solution designed into a device. The  
compartment door contains an oring which seals against the air hole side of the battery when the door  
is closed. The air plenum volume is defined by the compartment door and the sides of the oring. A  
slide switch is located in the compartment door to create an air access point. The slide switch acts as a  
valve which seals the compartment when in the closed position and allows air to flow to the battery  
when in the open position. The slide switch could be mechanically manipulated by the user or  
electronically controlled by the device.  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  
P a g e | 14  
Figure 12: Air Management Design Concept  
3.3 ‐‐ Battery Compartment  
The design of a Zinc Air Prismatic battery compartment depends on several factors including battery  
dimensions, battery orientation, and air flow needed to maintain power to the device. Other  
considerations are the ease of battery insertion and removal, contact materials, reversal protection, and  
the shape and location of device contacts. In general, consumers should be able to use and replace Zinc  
Air Prismatic batteries in a similar fashion to AA and AAA replaceable batteries with no additional  
actions required other than removing the tab from the Zinc Air Prismatic battery prior to use.  
Energizer Zinc Air Prismatic batteries are electrically conductive on all surfaces, and flat battery contacts  
are recommended. Leaf spring contacts are preferred over coil springs as coil springs are more prone to  
shorting. Positive contact should be made at the positive (+) can sidewall rather than on the air hole  
side of the battery to prevent unwanted air flow restrictions to the air holes. Negative contact should  
be centered on the negative () cup bottom (non air hole side of battery) in such a way as to minimize  
potential shorting between the negative cup and the positive can sidewall. Figure 13 illustrates the  
recommended contact surfaces for Zinc Air Prismatic batteries.  
Figure 13: Zinc Air Prismatic Polarity  
Contact surfaces area should be maximized to reduce contact resistance. Sufficient contact pressure  
should also be maintained to ensure consistent electrical connection but not so great as to deform the  
battery contacts. A contact force in the range of one half to two pounds is recommended.  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  
P a g e | 15  
Contact Materials:  
Nickel plated stainless steel is recommended because it provides good conductivity and environmental  
stability at a reasonable cost. Nickel plating must be adherent, continuous, and nonporous. The nickel  
plating must also resist the wear that occurs during the insertion and extraction of batteries. The  
suggested plating thickness is 56 micrometers.  
Battery Orientation:  
How the battery is situated in the compartment is an important design consideration. The location of  
the air access path, plenum, and seal are determined by the facing of the battery air holes. The  
orientation of the air hole side of the battery also influences the location of the electrical contacts.  
Determining the facing of the battery air holes is generally a function of device use and the position of  
the battery compartment within a device. Figure 14 presents an example of a device which orients a  
Zinc Air Prismatic battery with the air holes facing the compartment door. The cover holds the battery  
in place and does not restrict air flow to below what is required for device operation.  
Figure 14: Battery Orientation and Device Contacts  
Reversal Protection:  
Battery reversal protection is recommended for battery operated devices to prevent against possible  
damage to a device or battery if a battery is inserted incorrectly. Reversal protection can be mechanical  
or electronic, depending on the device. An example of mechanical reversal protection is a design  
feature in the battery compartment that only allows the battery to be inserted with the correct polarity.  
This can be accomplished by including a raised lip or ridge that conforms to the battery contour when  
inserted in the correct polarity. The recommended location of the rib for Energizer Zinc Air Prismatic  
batteries is where the recessed edge around the non air hole side of the battery fits into the  
compartment.  
Battery Dimensions:  
Similar to other battery systems, Zinc Air batteries can bulge slightly under normal discharge conditions  
as zinc is converted to zinc oxide in the intended reactions. Energizer recommends designing devices  
around standard industry dimensions where available. Typical dimensional specifications for Energizer  
Zinc Air Prismatic batteries, including consideration for possible bulge, can be found on the respective  
datasheets.  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  
P a g e | 16  
3.4 ‐‐ MultiBattery Applications  
In some situations, a higher voltage or an increased performance level is desired for a certain  
application. Zinc Air batteries can be arranged in series or in parallel as needed. Devices that use more  
than one Zinc Air Prismatic battery introduce additional design considerations. An air plenum and air  
access is required for each battery, and these can be independent or shared. Additionally, stacked  
batteries require space above the air hole side of each battery. If two batteries are stacked with the air  
hole sides facing each other, then a single air plenum can be used.  
3.5 ‐‐ Recommended Cutoff Voltage  
The recommended end of life for Zinc Air batteries is at 0.9 volts where essentially all available capacity  
has been used. Below 0.9 volts additional chemical reactions may take place in the battery which can  
lead to increased potential for gassing and leakage. Energizer recommends that devices are designed to  
prevent the battery from being discharged below 0.9 volts. This can be accomplished preferably by a  
complete disconnect of the battery circuit or by using a low voltage battery warning.  
3.6 ‐‐ Fuel Gauging  
Zinc Air Prismatic batteries have a relatively flat discharge curve compared to existing Alkaline solutions,  
with the discharge curve sloping more at increased discharge rates. This can be seen in Figure 4 and  
Figure 6. Although the relatively flat discharge curve makes the Zinc Air system more challenging to fuel  
gauge with conventional voltageonly measurements, the flat voltage profile helps make device  
performance consistent throughout the life of the battery. A more sophisticated algorithm  
incorporating additional measurements that are tailored to the specific application may be necessary.  
This is similar to what is required for Lithium Iron Disulfide and rechargeable Nickel Metal Hydride  
batteries.  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  
P a g e | 17  
Section 4: Handling Procedures  
4.1 ‐‐ Recommended Operating and Storage Conditions  
For optimum performance and capacity retention, Zinc Air Prismatic batteries should be used in a  
temperature range of 10C to 55C and in a relative humidity range of 25% to 80%. Zinc Air batteries  
should be stored between 10°C and 30°C and at 40% to 70% relative humidity. Batteries should be  
stored with the tab in place to prevent performance degradation due to environmental exposure. As  
with any chemical system, high temperature storage will result in increased loss of capacity.  
4.2 ‐‐ Polarity Markings  
The adhesive tab of the battery covers the positive can contact and is marked with a positive polarity (+)  
mark. In addition, a negative polarity () marking is etched on the metal cup to help users correctly  
insert the battery into the device battery compartment.  
4.3 ‐‐ Safety  
Energizer Zinc Air Prismatic batteries undergo safety and abuse testing according to alkaline and zinc air  
industry standards. Some of the tests performed include multiple temperature cycling, deep discharge,  
direct short, thermal abuse, abusive charge. Safety test performance is consistent with that of standard  
alkaline and indicates no safety concerns. Under standard conditions, minimal hydrogen gas can be  
generated as in other alkaline cells and cell thickness may increase slightly. Under abusive conditions,  
leakage is more likely to occur with increased cell thickness.  
In situations where the battery is operating or stored in temperatures and humidity outside the  
recommended ranges in Section 4.1, or under abusive conditions, the battery may produce a small  
amount of white precipitate (salting) on the crimp of the battery. Energizer recommends that the  
battery be disposed of if and when salting is observed. Exposed skin or clothing should be cleansed with  
cool soapy water.  
Because of their size, Zinc Air Prismatic batteries pose a swallowing / choking hazard. If batteries are  
swallowed, immediately contact the National Capital Poison Center collect at 2026253333 for medical  
advice.  
4.4 ‐‐ Battery Disposal  
Energizer does not add mercury or cadmium to Zinc Air Prismatic batteries therefore they are exempt  
from any special collection and disposal regulations after discharge.  
ENERGIZER BATTERY MANUFACTURING  
VERSION 1.2  

Admiral AAWV 06CR1FAU User Manual
Briggs Stratton Automobile Parts 525 SERIES User Manual
Epson Stylus TX200 User Manual
Epson Stylus TX430W User Manual
Fisher Price M7932 User Manual
Fujitsu All in One Printer RX7300E User Manual
Haier HWF05XC5 User Manual
Hamilton Beach 04152 User Manual
HoMedics Deluxe Shiatsu Massaging Cushion MCS 600H User Manual
HP Hewlett Packard Photosmart C4680 User Manual