Chauvet Automobile Accessories 900 User Manual

Snapshot  
OK on Dimmer  
Outdoor OK  
Hurricane900  
Sound Activated  
DMX512  
Master/Slave  
115V/230V Switch  
Replaceable Fuse  
User Serviceable  
Duty Cycle  
USER MANUAL  
3000 N 29th Ct, Hollywood, FL 33020 U.S.A.  
(800) 762-1084 (954) 929-1115  
FAX (954) 929-5560  
1. BEFORE YOU BEGIN  
What is included  
1 x Hurricane900  
1 x Wired Remote  
1 x Warranty Card  
1 x User Manual  
Unpacking Instructions  
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that  
all parts are present, and have been received in good condition. Notify the shipper immediately and  
retain packing material for inspection if any parts appear damaged from shipping or the carton itself  
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture  
must be returned to the factory, it is important that the fixture be returned in the original factory box  
and packing.  
AC Power  
To determine the power requirements for a particular fixture, see the label affixed to the back plate of  
the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average  
current draw under normal conditions. All fixtures must be powered directly off a switched circuit and  
cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer  
channel is used solely for a 0% to 100% switch. Before applying power to a fixture, check that the  
source voltage matches the fixture’s requirement. Check the fixture or device carefully to make sure  
that if a voltage selection switch exists that it is set to the correct line voltage you will use.  
Warning!  
Verify that the voltage select switch on your unit matches the line voltage applied.  
Damage to your fixture may result if the line voltage applied does not match the  
voltage indicated on the voltage selector switch. All fixtures must be connected to  
circuits with a suitable Earth Ground.  
Hurricane™ 900 User Manual  
3
12/23/2008 6:04 PM  
     
Contact Us  
World Wide  
General Information CHAUVET  
3000 North 29th Court  
Hollywood, FL 33020  
voice: 954.929.1115  
fax:  
toll free:  
954.929.5560  
800.762.1084  
Technical Support  
CHAUVET  
3000 North 29th Court  
Hollywood, FL 33020  
voice: 954.929.1115 (Press 4)  
fax:  
954.929.5560 (Attention: Service)  
World Wide Web  
Hurricane™ 900 User Manual  
4
12/23/2008 6:04 PM  
   
Safety Instructions  
Please read these instructions carefully, which includes important  
information about the installation, usage and maintenance of this  
product.  
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that  
they also receive this instruction booklet.  
Always make sure that you are connecting to the proper voltage, and that the line voltage you are  
connecting to is not higher than that stated on the decal or rear panel of the fixture.  
This product is intended for indoor use only!  
To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no  
flammable materials close to the unit while operating.  
The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent  
surfaces. Be sure that no ventilation slots are blocked.  
Always disconnect from power source before servicing or replacing lamp or fuse and be sure to  
replace with same lamp source.  
Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use  
its carrying handles.  
Maximum ambient temperature (Ta) is 104°F (40°C). Do not operate fixture at temperatures higher  
than this.  
In the event of a serious operating problem, stop using the unit immediately. Never try to repair the  
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please  
contact the nearest authorized technical assistance center. Always use the same type spare parts.  
Never connect the device to a dimmer pack.  
Make sure the power cord is never crimped or damaged.  
Never disconnect the power cord by pulling or tugging on the cord.  
Avoid direct eye exposure to the light source while it is on.  
Caution!  
There are no user serviceable parts inside the unit. Do not open the housing or  
attempt any repairs yourself. In the unlikely event your unit may require service,  
please contact CHAUVET at: 954-929-1115.  
Hurricane™ 900 User Manual  
5
12/23/2008 6:04 PM  
2. INTRODUCTION  
Features  
Output: 4,000cfm  
1.3L tank capacity  
5 minute heat up  
Manual fog button  
Wired remote included  
LED-illuminated tank  
Water-based fogger  
OPTIONS  
Wired timer remote (FC-T)  
Wireless remote (FC-W)  
Fluid  
reservoir  
cap  
Product Overview  
Manual  
fog button  
Fluid level  
indicator  
Remote  
control  
connection  
Fuse  
cover  
Power  
input  
Power  
on/off  
Hurricane™ 900 User Manual  
6
12/23/2008 6:04 PM  
     
Mounting  
ORIENTATION  
This fixture may be mounted in a 90° degree angle only, provided there is adequate room for  
ventilation.  
RIGGING  
Hanging Clamp  
It is important never to obstruct the fan or vents pathway. Mount the  
fixture using, a suitable “C” or “O” type clamp. Adjust the angle of the  
fixture by loosening both knobs and tilting the fixture. After finding  
the desired position, retighten both knobs.  
When selecting installation location, take into consideration lamp  
replacement access and routine maintenance.  
Safety cables must always be used.  
Never mount in places where the fixture will be exposed to rain, high  
humidity, extreme temperature changes or restricted ventilation.  
Note!  
Clamp is sold separately.  
Hanging  
bracket  
Bracket  
adjustment  
knob  
Hurricane™ 900 User Manual  
7
12/23/2008 6:04 PM  
     
3. OPERATING INSTRUCTIONS  
Operation  
This mode will allow you to control the fogger manually, set the fog machine to run continuously, or to set the  
fog machine to run off bursts with adjustable interval and duration settings.  
Manual Remote Operation (FC-M) (Optional)  
1. Plug in the fog machine to power and turn the power switch to the fixture on.  
2. Plug in the wired manual remote to the Remote Control socket on the rear of the fog machine.  
3. Press the single button located on the remote to trigger the fog output.  
Note: The button is momentary, which means that the fog machine will only output while the  
button is pressed. Once the button is released, the fog will stop outputting.  
Timer Remote Operation (FC-T) (Optional)  
1. Plug in the fog machine to power and turn the power switch to the fixture on.  
2. Plug in the timer remote to the Remote Control socket on the rear of the fog machine.  
3. Press the TIMER ON/OFF button on the timer remote. The LED above the button should light, indicating  
activation of function.  
4. You may now set the INTERVAL & DURATION adjustment knobs to the desired position.  
Note: The INTERVAL is the time in between bursts of fog.  
Note: The DURATION is the time that the fog machine will run during the burst.  
Duration  
Interval  
Adjustment  
Adjustment  
Timer LED  
Indicator  
Manual  
Momentary  
LED  
Manual/Power LED  
Indicator  
Manual control  
momentary button  
Timer latching  
button  
Continuous  
latching button  
Hurricane™ 900 User Manual  
8
12/23/2008 6:04 PM  
       
Wireless Controller (FC-W) (Optional)  
This mode will allow you to control the fogger using the optional wireless controller. This consists of the  
transmitter and the receiver. You may control up to 4 independent fog machines or many more if you run them  
simultaneously. See the below instructions on setting up your fogger to operate with the FC-W.  
1. Plug the wires receiver into the fog machine 5-pin port labeled “Remote Control”.  
2. There are 4 buttons on the wireless remote transmitter which act as triggers. Each button can be assigned to a  
different fog machine. You may only choose 1 dipswitch on each receiver. See the below configuration for  
setting the receivers to operate with the transmitter remote.  
Mode  
Dipswitches  
CH1  
1 = On, 2-4 = Off  
CH2  
CH3  
CH4  
2 = On, 1,3,4 = Off  
3 = On, 1,2,4 = Off  
4 = On, 1,2,3 = Off  
3. Press the fog button, and the fog machine will output fog for as long as you hold down the button.  
LED indicator  
(ready)  
LED indicator  
(heating)  
Dipswitches  
Wireless  
Transmitter  
Fog  
Triggers  
Wireless  
Receiver  
Hurricane™ 900 User Manual  
9
12/23/2008 6:04 PM  
 
Disconnect the power cord before replacing a fuse and always  
replace with the same type fuse.  
Fuse Replacement  
With your hands, unscrew the fuse holder from its housing. Remove the damaged fuse from its holder  
and replace with exact same type fuse. Screw  
the fuse holder back in its place and reconnect  
power.  
The fuse is located  
inside this  
compartment.  
FUSE  
General Troubleshooting  
Applies to  
Foggers  
& Snow  
Dimmers  
& Chaser  
Symptom  
Solution(s)  
Lights  
Controllers  
Loss of signal  
Use only DMX cables  
Install terminator  
Note: Keep DMX cables separated from power cables  
or black lights.  
Relay will not work  
Check reset switch  
Check cable connections  
Remote does not  
work  
Make sure connector is firmly connected to device  
If you still have a problem after trying the above solutions, please contact CHAUVET Technical  
Support at the location listed below.  
Technical Support  
Address: Service Dept.  
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.)  
Support (Email): [email protected]  
Telephone: (954) 929-1115 - (Press 4)  
Fax: (954) 929-5560 - (Attention: Service)  
Hurricane™ 900 User Manual  
10  
12/23/2008 6:04 PM  
     
4. APPENDIX  
General Maintenance  
To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage  
and environment are contributing factors in determining frequency. As a general rule, fixtures should  
be cleaned at least twice a month. Dust build up reduces light output performance and can cause  
overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off  
fixture before conducting maintenance.  
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust  
collected on external vents and internal components. Clean all glass when the fixture is cold with a  
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply  
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical  
surfaces until they are free of haze and lint.  
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to  
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:  
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s  
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean  
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.  
Returns Procedure  
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.  
Package must be clearly labeled with a Return Merchandise Authorization Number (RMA #).  
Products returned without an RMA # will be refused. Call CHAUVET and request RMA # prior to  
shipping the fixture. Be prepared to provide the model number, serial number and a brief description  
of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from  
inadequate packaging is the customer’s responsibility. CHAUVET reserves the right to use its own  
discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is  
always a safe method to use.  
Note:  
If you are given an RMA #, please include the following information on a piece of  
paper inside the box:  
1) Your name  
2) Your address  
3) Your phone number  
4) The RMA #  
5) A brief description of the symptoms  
Claims  
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be  
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and  
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim  
for items such as missing component/part, damage not related to shipping, and concealed damage,  
must be made within seven (7) days of receiving merchandise.  
Hurricane™ 900 User Manual  
11  
12/23/2008 6:04 PM  
       
Technical Specifications  
WEIGHT & DIMENSIONS  
Length ................................................................................................................................ 9.7 in (248 mm)  
Width.................................................................................................................................. 8.9 in (228 mm)  
Height................................................................................................................................. 8.6 in (220 mm)  
Weight..................................................................................................................................7.7 lbs (3.5 kg)  
POWER  
AC Power (voltage specific) ....................................................................115VAC 60Hz or 230VAC 50Hz  
Fuse ...............................................................................................................................................2A 250V  
Power Consumption .........................................................................................404W (3.3A) max @ 120V  
Inrush Power........................................................................................................................(3.3A) @ 120V  
Power Factor...........................................................................................................................1.00 @ 120V  
THERMAL  
Maximum ambient temperature .............................................................................................104°F (40°C)  
ORDERING INFORMATION  
Hurricane900...............................................................................................................HURRICANE900  
WARRANTY INFORMATION  
Warranty..................................................................................................................1-year limited warranty  
Hurricane™ 900 User Manual  
12  
12/23/2008 6:04 PM  
 

Brother MFC 3200c User Manual
Brother MFC 7300C User Manual
Bryant 452 User Manual
Bryant DE LUXE 12 SEER 552A User Manual
Friedrich P12A User Manual
Fujitsu Air Conditioner ASU9CQ User Manual
Fujitsu FJBC GP User Manual
Goodman Mfg CKLB30 1E User Manual
Graco Bumper Jumper 4E02LJG User Manual
Hisense Group KFR 28GWE User Manual