This product is designed for household use only.  
IMPORTANT SAFEGUARDS  
When using electrical appliances, basic safety precautions should always be followed:  
1. Read all instructions  
2. To protect against fire, electric shock and personal injury, do not immerse cord, plugs, or the unit in  
water or other liquid.  
3. Close supervision is necessary when the product is used around the chirldren. This product is not  
intended for use by chirdren.  
4. Do not operate the product with a damaged cord/plug. If the plug is damged in any manner, please  
return the product for repair.  
5. Always keep the product in an upright position.  
6. During the transit, the product could be placed up side donwn, which may cause the oil in the  
compressor drain into the refrigerant tubes reducing the cooling efficiency. Thus, before using the  
product, keep the product in a upright position for 1~2 hours.  
7. Connect the product to a properly grounded power supply. Do not use an adapter plug or extension  
cord.  
8. Do not cover or insert any object into the air inlet and/or outlet.  
9. Turn off the power when no one is in the room.  
10. Do not place anything in the direct path of the airflow.  
11. Do not place the product near any heat source or where gas leakage may occur.  
12. Do not use the product near a bath, shower, or swimming pool, or in any other steamy, or wet areas.  
13. Do not turn off/on the product by plugging or unplugging the power cord directly.  
14. Do not modify the power cord or share the outlet with other appliances.  
15. Unplug the product from the outlet when not in use and before cleaning.  
16. Attachments not recommended by the manufacturer as they may cause injuries.  
17. Do not expose skin, face and eyes directly to cool air for a long period of time.  
18. If an abnormal odor or smoke comes from the product, disconnect the unit immediately and bring to a  
qualified service technician.  
19. Unplug the power from wall outlet before cleaning the filter and do not touch the metal parts inside.  
20. Do not apply any kind of insecticide or flammable spray onto or into the unit.  
21. Do not step on the product or place objects on the unit.  
22. Place the product on a steady and flat surface, or the water may slip out of the water tank.  
23. Before storing the product, always drain the water from the unit and clean the filter.  
24. Do not use the product for other than it’s intended use.  
The manufacturer disclaims any responsibility if the above instructions are not followed.  
The manufacturer reserves the right to make technical changes without notice.  
SAVE THESE INSTRUCTIONS  
This product is designed for household use only  
- 3-  
LCDI POWER CORD AND PLUG  
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and  
plug. The LCDI power cord and plug will shut off the supply source via electrical disconnect (circuit trip) if the  
nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.  
The cord will not be able to conduct power until the devise has been manually reset. This device provides  
protection to reduce the risk of fire due to arcing faults in the power cord. The cord shields are not grounded  
and they must be considered as shock hazards if exposed. The cord shield must not be connected to ground  
or to any exposed metal.  
To ensure if the plug is working properly, please follow the following instructions to test it:  
1. Plug power cord into wall outlet.  
2. Press TEST button. The circuit should trip, cutting power to the air conditioner.  
3. Press RESET button for use.  
DO NOT USE IF ABOVE TEST FAILS.  
In the event the LCDI Plug of the power cord trips by itself,  
then first examine the cord for any damage. If there is no  
damage to the cord, then press the RESET Button. If the LCDI  
Plug trips again, then immediately unplug the power supply  
cord and contact a professional technician or service center.  
WARNING:  
1. Do not use the TEST and RESET buttons as “ON”  
and “OFF” switches.  
2. Do not press the TEST button while the air conditioner  
is operating  
3. The cord and plug are designed for indoor use only.  
4. Periodically examine the cord for any damage. If the shield gets exposed, immediately unplug the  
power cord and do not use the unit.  
- 4-  
PARTS NAMES  
Features:  
1. 3 in 1 portable air conditioner, cooling, fan and dehumidifying function.  
2. Colorful LED display with remote control.  
3. Quiet and easy operation.  
4. Auto defrosting function.  
5. 24 hour timer on/off function.  
6. Auto swing function of horizontal.  
7. Three minutes restart delay to protect compressor.  
- 5-  
INSTALLATION  
1. Select a proper installation location  
Place the portable air conditioner on a flat and dry location where the air  
outlets cannot be obstructed. Leave a 20” (50 cm) minimum space between  
the product and the wall.  
Adapter B  
2. Assemble the air exhaust hose  
Connect the end of the hose and adapter-  
twist them.  
Adapter A  
3. Connection of hot air exhaust hose  
1). Assemble the hot air exhaust hose connector as follows. Do not use excessive force as adaptor may  
be damaged.  
2). Extend the exhaust pipe, put one side of it into the hot air exhaust outlet. Turn it counter clock wise at  
least 5 turns and then put the other side into the hose connector and turn it clock wise.  
3). Put the sliding bar on the window. It’s designed to fit most standard vertical and horizontal windows.  
- 6-  
4. Install the window kits  
Your window kit has been designed to fit most standard "vertical" and "horizontal" window applications.  
However, it may be necessary for you to improvise/modify some aspects of the installation procedures for  
certain types of windows.  
Notes:  
The length of hot air exhaust hose is between 11to 59〞  
The length of the hot air exhaust hose is designed especially according to the specifications of the air  
conditioner, do not use an extension or a longer replacement hose as that may cause a malfunction.  
Do not bend or twist the hot air exhaust hose more than (45°)angle.  
- 7-  
OPERATING INSTRUCTION  
1.Control panel  
Cautions: If the unit is turned off in cool mode and restarted immediately, it will wait in 3 minutes at least  
before running.  
r
s
t
p
q
n
o
POWER  
Press this button to turn on/off the unit.  
n
o
p
MODE  
Press this button to select cool , fans or dehumidify function.  
SWING  
Press this button to make the horizontal louver swing. To stop swing , press  
this bottom again.  
FAN  
Fan speed setting.  
q
TIMER  
Press this button to enter time-setting status.  
r
st  
UP/DOWN  
Press up or down button to set temperature or adjust the timer in timer  
setting .press both buttons to convert from Celsius to Fahrenheit.  
- 8-  
2. LED Indicator  
Temperature and time indicator  
Cooling mode indicator  
Fan mode indicator  
Dehumidifying indicator  
Sleep mode indicator  
Auto mode indicator  
Timer mode indicator  
Low fan speed indicator  
High fan speed indicator  
Swing function indicator  
3. Remote control  
Press this button to turn on / off the unit.  
POWER  
Press this button to select Auto, Cooling, Fan or  
Dehumidifying mode.  
MODE  
Press this button to select High or Low fan speed  
FAN  
Press this button to turn on / off the auto swing  
function.  
SWING  
Press this button to set up time  
TIMER  
ECON  
Press this button to force the unit into a strong  
cooling mode without any limitation of room  
temperature in cooling mode.  
Press this button to active or cancel sleep function  
in cooling mode.  
SLEEP  
Press this button to adjust time or temperature.  
Press the two buttons simultaneously to select or  
in in display.  
UP/DOWN  
- 9-  
OPERATING INSTRUCTION  
1. Simple steps to use cooling mode  
Plug in the power cord and press the “POWER” button  
Press “MODE” to chose COOLING mode.  
Press “UP” or “DOWN“ to set the desired temperature. The temperature ranges from 59F to  
86F(15C~30C)  
Press, “SPEED” to set a desired fan speed.  
The fan will run first. After few minutes, the compressor will start to run if the room temperature is higher  
then the setting temperature. The compressor will stop running when the room temperature is below the  
setting temperature.  
2. Setting the timer  
(1) Turn off the unit automatically:  
When the unit is running, press TIMER to set operating duration, and then the LED will flash five times.  
During this period of time, press Up or Down button to adjust setting time from 0.5 hr. to 24 hr. After  
setting, the LED will flash five times and then display the room temperature again. When the operating  
duration reaches the pre-set time, the power will turn off automatically.  
(2) Turn on the unit automatically:  
When the unit is off, press TIMER to set start time, and then the LED will flash five times. During this  
period of time, press Up or Down button to adjust setting time from 0.5 hr. to 24 hr. After setting, the  
LED will flash five times and then display the temperature again. Once the pre-set time is reached, the  
power will turn on automatically.  
(3) Change the setting:  
When TIMER is on, you can check the remaining time by pressing the TIMER button. It will flash five  
times. Press Up or Down button to adjust the timer. The timer can be canceled if you press the TIMER  
button once again when LED is flashing.  
Attention:  
If the unit is suddenly turned off during operation, the compressor will start to run three minutes after  
the power is turned back on.  
3. Setting operating mode  
ƒ COOLING: When this mode is selected, the fan will run first and then the compressor will start to run  
five minutes after the power is on. To set your desired temperature, press UP or DOWN button. The  
temperature ranges from 15C~30C (59F~86F). When the room temperature is lower than the setting  
temperature, the compressor will stop running until the room temperature is higher than setting  
temperature. In this case, only the fan will keep running.  
ƒ FAN: When this mode is selected, the temperature setting cannot be changed, but you can set your  
desired speed. There is no need to use the air exhaust duct in this mode.  
ƒ DEHUMIDIFING: When this mode is selected, it presets the fan speed and mode, and these settings  
cannot be changed. Under this mode, the compressor will not run, and LED will display room  
temperature. There is no need to use the air exhaust duct. You may need to drain water with the drain  
pipe if the humidity is very high.  
4 .Setting temperature  
In COOLING mode, press the “UP” button to increase the temperature setting or press the “DOWN  
“ button to lower the temperature setting. When the number is flashing, it indicates the temperature you  
are setting up. When the number is lit but not flashing, it indicates the current room temperature.  
5. Setting fan speed  
In COOLING and FAN mode, press “SPEED” to adjust the fan speed. There are high, medium and low  
modes. Each fan speed corresponds to one indicator on LED control panel. Please note: when unit is in  
dehumidifier mode, the fan speed cannot be adjusted.  
- 10-  
6. Auto  
Press MODE button to select Auto mode. The unit will run cooling / fan / dehumidifying according to the  
room temperature as following:  
a. Cooling: 27room temperature 40℃  
b. Fan: 21room temperature 27℃  
c. Dehumidifying: 5℃ < room temperature 21℃  
7. Auto defrost  
When the air conditioner is used in the cooling or dehumidifying mode in low room temperature conditions  
it will develop internal frost. When the frost gets to heavy and the efficiency is being compromised the unit  
will go into a defrost mode automatically and E4 will be displayed. The unit will restart automatically after  
the frost has been dissipated.  
Suggestion: Do not have the air conditioner running in the cooling or dehumidify mode when the  
room temperature is below 15℃(59F).  
8. Sleep Function  
To active or cancel the sleep function by remote control under cooling mode.  
The unit will run at low fan speed as default with lower noise. The setting temperature will increase 1℃  
per 2 hour running time, and it will not change after increasing 2.  
Suggestion: Select sleep function when you’re in sleeping.  
9. Dehumidify  
Press MODE button to select dehumidify mode, the unit will run at low fan speed as default. And the  
setting temperature will be invalid, display shows room temperature 7~35℃(45~95F) only.  
- 11-  
WATER DRAINAGE  
The water tank in the unit will fill when the air conditioner is used in the dehumidifying mode or run in an  
area with high humidity.  
When water tank is full, water full indicator will light and display will show P2 as alarm, the air conditioner  
will be shut off automatically. Then you need to drain the water and restart the air conditioner as follows:  
1. Unplug the unit.  
2. Put a vessel such as water tank under the drainage port.  
3. Remove the drainage cap and water stopper.  
4. Drain out the water fully.  
5. Insert the water stopper and screw down the drainage cap.  
6. Plug in and restart the air conditioner.  
Drainage port  
Water stopper  
Drainage cap  
Cautions:  
Move the air conditioner carefully when the water tank is full to prevent spillage.  
The water tank capacity in air conditioner is 0.7L.  
- 12-  
MAINTENACE  
Turn off the unit and pull out the plug from socket before any cleaning or maintenance.  
Cleaning  
1. Surface cleaning  
Clean the surface of air conditioner with a duster or half-wet soft cloth.  
Do not use chemical solvent like benzene, alcohol, gasoline and etc. or the surface may be damaged or  
even deformed.  
2. Air filter cleaning  
The efficiency will be reduced if the air filter is blocked with a lot of dust. It is  
recommended that the filters are cleaned every two weeks.  
z Take out the two filters as show in the following picture.  
z Wash the air filters by immersing them into warm (below 40or 104) water with neutral detergent and  
dry them at room temperature.  
z Put the air filter back to its original position.  
After season maintenance and storage  
z Remove the water stopper to empty the water in the air conditioner.  
z Clean air filter.  
z Have the air conditioner run in fan mode at low fan speed for 4hours, to ensure the internal air conditioner  
is dry, to avoid any mildew growth in it.  
z Turn off the unit, pull out the plug, put the power cord on the collection of rear panel of unit.  
z Remove the hot air exhaust hose & connector.  
z Take the batteries out of the remote control.  
z Wrap the air conditioner with plastic bag and keep it with all accessories in a dry place.  
- 13-  
TROUBLE SHOOTING  
Please check the air conditioner by yourself referring to the following chart before contacting  
professional service.  
Trouble  
Reason  
Is no power supply?  
Is water full?  
Solution  
Plug in and turn on the unit.  
Drain out the water and restart the unit.  
Please use only when the room  
temperature between 5-40℃  
Cancel Timer function  
The unit doesn’t  
work  
Is the room temperature too high?  
Is Timer function activated?  
Is the unit in direct sunlight?  
Draw the curtains  
Is the door or window opened? Is Close the window and door. Turn off or  
there any heat source in the room?  
Is the filter very dirty?  
Is air inlet outlet blocked?  
move the heat source.  
Clean or change the air filter  
Clear out the blockage.  
The unit does  
not seem to  
perform.  
Is the room temperature lower than  
setting temperature?  
Adjust the setting temperature  
The unit noise is  
high  
Put the unit on flat and hard  
place  
Is the unit not on flat place?  
Re-start the unit after 3 minutes when  
the temperature of compressor is  
reduced.  
Compressor  
doesn’t work  
Is overheat protection of compressor  
activated?  
Is the distance too far from the unit?  
Is the signal not received by unit?  
Is the battery exhausted?  
Use remote control near the unit and  
make sure it aims at the remote control  
receiver on the unit.  
Remote control  
doesn’t work  
Change new battery.  
NOTE: Stop running the unit and pull out the plug if the problem is beyond the trouble shooting chart,  
and call service center for help. Don’t repair or disassemble the unit by yourself to avoid any damage.  
APPENDIX  
Technical parameters  
Air-conditioner  
Serial No. ****  
YPM-06C  
MODEL  
RATED COOLING  
REFRIGERANT/CHARGE  
POWER SUPPLY  
RATED CURRENT  
HIGH/LOW PRESSURE  
NOISE  
5000BTU  
R410a/260g  
110-120V/60Hz  
7.5A  
3.5/1.0MPa  
54dB (A)  
*******  
Conforms to UL STD. 484  
Certified to CSA STD. C22.2 No.92  
NET WEIGHT  
19kg  
DIMENSION(L*D*H)  
310*296*850mm  
YOAU ELECTRIC CO.,LTD  
Motor-Compressor Thermally Protected  
Risk of electric shock. Disconnect Power before Servicing Unit  
There is no further notice for the change of the parameters above, please refer the exact  
parameters base on the rating plate  
*Do not dispose this product as unsorted municipal waste. Have refrigerant removed by a  
qualified service technician before disposing of this unit .  
- 14-  

Briggs Stratton 8F User Manual
Brother MFC 7450 User Manual
Brother MFC 9200C User Manual
Cornelius 318949000 User Manual
Danby DESIGNER DAC9003D User Manual
Energizer 3 335NNCI User Manual
Haier HPU 44H03 User Manual
Heat Controller Inc Air Conditioner DMH18DB 1 User Manual
Honeywell s HercuLine 2000 User Manual
HP Hewlett Packard OfficeJet LX User Manual