EMERSON RC188 User Manual

BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 1  
READ AND SAVE THESE INSTRUCTIONS  
Ceiling Fan/Light  
Receiver & Reverse Module  
Owner's Manual  
For Use With SR600 Remote Control,  
SR650 Remote Control and SW605 Wall Control  
Receiver Model Numbers:  
RC188 &  
RC212  
6-Speed Receiver  
RC188 Receiver Supplied with Reverse Module for 188 Motor Fans  
with Small Canopies  
RC212 Receiver Supplied with  
Reverse Module for 212 Motor Fans  
RC188 Receiver & Module For Use Only with Emerson Ceiling Fan  
Models: CF755, CF770, CF775, CF940, CF935, CF670, CF690 & CF695  
RC212 Receiver and Module for Use Only with Emerson Ceiling Fan  
Model CF787  
Part No. F40BP74150000  
Form No. BP7415  
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 3  
General  
SECTION ONE:  
Your Emerson Ceiling Fan may be used  
with a SR600 or SR650 Remote Control, a  
SW605 Wall Control, and a RC188/RC212  
6-speed Receiver. The remote control or  
wall control is designed to control your  
ceiling fan speed, airflow direction, and  
light intensity.  
SR600 REMOTE  
CONTROL PROCEDURES  
General  
Your Emerson Ceiling Fan/Light SR600  
Remote Control consists of hand-held  
transmitter and a receiver which is  
mounted under the fan ceiling cover. The  
remote control is designed to separately  
control your ceiling fan speed and light  
intensity.  
NOTE: The RC188 Receiver is to be  
used with the following Emerson  
ceiling fan models: CF940, CF935,  
CF755, CF770, CF695, CF690 & CF670.  
NOTE: The RC212 Receiver is to be  
used with the CF787 Emerson ceiling  
fan.  
The remote control transmitter is powered  
by two AAA alkaline batteries (included).  
To prevent possible damage if the  
batteries should leak, be sure to remove  
the batteries when the control is not to be  
used for an extended period of time.  
Unpackaging  
The carton with the RC188 or RC212  
Receiver also contains  
a
reversing  
Code switches in the transmitter and  
receiver may be set in 32 different  
positions. If your fan and light go on and  
off without using your control, you may be  
getting interference from other remote  
units such as garage door openers, car  
alarms or security systems. To remedy this  
situations, simply change the combination  
code in your transmitter and receiver.  
module, seven wire connectors, four pull  
chain switch plugs, and two rectangular  
switch plugs.  
The carton with the SR650 Remote  
Control contains a storage bracket with  
two mounting screws.  
The carton with the SW605 Wall Control  
contains three switch covers; ivory, white  
and almond color.  
Preset Memory Feature  
Your Emerson receiver is equipped with a  
preset memory feature. If the AC supply to  
the receiver is powered through a wall  
switch, when the switch is turned OFF, the  
control will remember the light intensity  
and fan speed. When the switch is turned  
back ON the light and fan will resume  
operation as they were prior to the switch  
being turned OFF.  
IMPORTANT  
This Owner’s Manual is divided into three  
sections. The first section, SR600/SR650  
REMOTE CONTROL PROCEDURES,  
describes how to install the two AAA  
alkaline batteries in the SR600 remote  
control transmitter and two CR2032  
Lithium batteries in the SR650 remote  
control transmitter, and how to set the  
operating frequency of the transmitter  
and receiver. The second section  
describes how to install the SW605 Wall  
Control. These instructions must be  
performed prior to installation of the  
ceiling fan as described in the third  
section, CEILING FAN PROCEDURES.  
Installation of Battery  
1. Remove the battery cover by pressing  
firmly below the arrow and sliding the  
cover off the control (Figure 1).  
2. Install two AAA alkaline batteries and  
reinstall the battery cover.  
3
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 4  
1. Slide the five switch levers in the  
REMOTE CONTROL  
LEVERS  
remote control to your choice of ON  
(up) or down positions. Use a ball-point  
pen or small screwdriver and slide the  
levers firmly up or down.  
ON  
1
2
3
4
5
I
TWO AAA  
BATTERIES  
2. When power is restored, push and hold  
the fan OFF button ( ) for 3 to 5  
seconds to set the code in the receiver.  
3. If airflow is desired in the opposite  
direction, press the ( ) button on the  
wall control. The fan must be operating  
at any speed for the reverse button to  
function. The blades will turn in the  
opposite direction and reverse the  
airflow.  
CODE  
SWITCHES  
BATTERY  
SR600 REMOTE  
CONTROL  
COMPARTMENT  
COVER  
Figure 1  
Installation of Storage  
Bracket for SR600  
Remote Control  
4. To set the desired fan speed, press the  
( ) button to decrease the speed and  
the ( ) to increase the speed. The  
LED display will light up to indicate the  
new speed selected.  
A storage bracket is provided for holding  
your remote control when not in use. If you  
desire to use the bracket, install it on a  
wall that is away from excess heat or  
humidity (Figure 2).  
5. To set the light intensity, press and  
release the LIGHT (  
) button to  
decrease the light intensity and the  
LIGHT ( ) button to increase the light  
intensity. The light will turn on at the  
light intensity previously selected.  
TO INSTALL BRACKET TO WALL:  
SLIDE THE COVER UP TO EXPOSE THE SCREW  
HOLES FOR INSTALLATION  
6. The sixth switch marked ON and I is for  
dimming control of lights: Set switch to  
ON to allow for dimming of the lights.  
Set switch to I for no dimming of the  
lights such as for fluorescent bulbs.  
COVER  
WALL  
BRACKET  
SR650 REMOTE  
CONTROL PROCEDURES  
SCREW  
HOLES (2)  
General  
Your Emerson Ceiling Fan/Light SR650  
Remote Control consists of hand-held  
transmitter with wall mount and a receiver  
which is mounted under the fan ceiling  
cover. The remote control is designed to  
separately control your ceiling fan speed  
and light intensity.  
Figure 2  
Setting Operating  
Frequency of SR600  
Remote Control  
The remote control transmitter is powered  
by two CR2032 Lithium batteries  
(inculded). Be sure to remove the batteries  
when the control is not to be used for an  
extended period of time.  
Your remote control has code switches  
which must be set in one of 32 possible  
code combinations. The five levers  
(numbered 1, 2, 3, 4, and 5) on the  
switches are factory-set in the ON (up)  
position. Change the switch settings as  
follows:  
Code switches in the transmitter and  
receiver may be set in 32 different  
positions. If your fan and light go on and  
off without using your control, you may be  
getting interference from other remote  
4
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 5  
units such as garage door openers, car  
alarms or security systems. To remedy this  
situations, simply change the combination  
WALL  
BRACKET  
code in your transmitter and receiver.  
Preset Memory Feature  
Your Emerson receiver is equipped with a  
preset memory feature. If the AC supply to  
the receiver is powered through a wall  
switch, when the switch is turned OFF, the  
control will remember the light intensity  
and fan speed. When the switch is turned  
back ON the light and fan will resume  
operation as they were prior to the switch  
being turned OFF.  
SCREW  
HOLES (2)  
Figure 4  
Setting Operating  
Frequency of SR650  
Remote Control  
Installation of Battery  
1. Remove the battery cover by pressing  
firmly below the arrow and sliding the  
cover off the control (Figure 3).  
Your remote control has code switches  
which must be set in one of 32 possible  
code combinations. The five levers  
(numbered 1, 2, 3, 4, and 5) on the  
switches are factory-set in the ON (up)  
position. Change the switch settings as  
follows:  
2. Install one CR2032 Lithium battery into  
the battery compartment then stack the  
other CR2032 Lithium battery on top of  
the installed battery and reinstall the  
1. Slide the five switch levers in the  
remote control to your choice of ON  
(up) or down positions. Use a ball-point  
pen or small screwdriver and slide the  
levers firmly up or down.  
battery cover.  
REMOTE CONTROL  
LEVERS  
ON  
1
2
3
4
5
I
CODE  
SWITCHES  
2. When power is restored, push and hold  
SR650 REMOTE  
CONTROL  
the fan OFF button ( ) for 3 to 5  
seconds to set the code in the receiver.  
3. If airflow is desired in the opposite  
direction, press the ( ) button on the  
wall control. The fan must be operating  
at any speed for the reverse button to  
function. The blades will turn in the  
opposite direction and reverse the  
airflow.  
TWO CR2032  
LITHIUM  
BATTERIES  
(stacked)  
BATTERY  
COMPARTMENT  
COVER  
4. To set the desired fan speed, press the  
Figure 3  
( ) button to decrease the speed and  
the ( ) to increase the speed. The  
Installation of Storage  
Bracket for SR650  
Remote Control  
LED display will light up to indicate the  
new speed selected.  
5. To set the light intensity, press and  
release the LIGHT (  
) button to  
A storage bracket is provided for holding  
your remote control when not in use. If you  
desire to use the bracket, install remote  
control storatge bracket using the two  
screws provided. Install on a wall that is  
away from excess heat or humidity  
(Figure 4).  
decrease the light intensity and the  
LIGHT ( ) button to increase the light  
intensity. The light will turn on at the  
light intensity previously selected.  
6. The sixth switch marked ON and I is for  
dimming control of lights: Set switch to  
ON to allow for dimming of the lights.  
Set switch to I for no dimming of the  
lights such as for fluorescent bulbs.  
5
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 6  
Installation of Wall Control  
SECTION TWO:  
SINGLE-POLE INSTALLATION  
Setting Operating  
Frequency of SW605  
Wall Control  
(Figure 6)  
SW605 FAN/LIGHT  
HOT  
BLK  
WALL CONTROL  
Your wall control has code switches which  
must be set in one of 32 possible code  
combinations (Figure 5). The five levers  
(numbered 1, 2, 3, 4, and 5) on the  
switches are factory-set in the ON (up)  
position. Change the switch settings as  
follows:  
BLACK  
NEUTRAL  
GROUND  
RECEIVER LOCATED  
WITHIN THE CEILING  
COVER  
1. Slide the five switch levers in the wall  
control to your choice of ON (up) or  
down positions. Use a ball-point pen or  
small screwdriver and slide the levers  
firmly up or down.  
Figure 6  
!
WARNING  
2. When power is restored after  
installation of the wall control, push and  
Turning off wall switch is not sufficient.  
To avoid possible electrical shock, be  
sure electricity is turned off at the main  
fuse or circuit breaker box before wiring.  
All wiring must be in accordance with  
National and Local codes and the ceiling  
fan must be properly grounded as a  
precaution against possible electrical  
shock.  
hold the fan OFF button (  
) for  
3 to 5 seconds to set the code in the  
receiver.  
3. The sixth switch marked ON and I is for  
dimming control of lights: Set switch to  
ON to allow for dimming of the lights.  
Set switch to I for no dimming of the  
lights such as for fluorescent bulbs.  
CAUTION: To reduce the risk of  
electrical shock, disconnect the  
electrical supply circuit before  
installing the fan, light kit or receiver.  
WALL CONTROL  
CODE SWITCHES  
ON  
NOTE: Make all wiring connections  
using wire connectors (supplied). Make  
sure that all connections are tight,  
including ground, and that no bare wire  
is visible at the wire connectors, except  
for the ground wire.  
1
2
3
4
5
I
1. Disconnect electrical power to the  
branch circuit at the circuit breaker or  
fuse box before attempting to install the  
ceiling fan wall control into the outlet box.  
WALL  
CONTROL  
CODE  
SWITCHES  
2. Remove faceplate and screws from  
existing wall control. Pull control out  
from the wall box. Determine the “hot”  
wire and the “load” wire and disconnect  
these wires from control. Do not  
attempt to disconnect any wires not  
already connected to existing control.  
Figure 5  
3. Before installing wall control, place wall  
control in “OFF” mode by pushing  
“ON/OFF” switch to the “OFF” position.  
6
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 7  
3-WAY INSTALLATION  
(On fan controlled by two different wall  
controls) (See Figures 8 and 9.)  
!
WARNING  
Do not connect any neutral (white) wire to  
this control. Incorrect wiring will damage  
this control.  
!
WARNING  
Turning off wall switch is not sufficient.  
To avoid possible electrical shock, be  
sure electricity is turned off at the main  
fuse or circuit breaker box before wiring.  
All wiring must be in accordance with  
National and Local codes and the ceiling  
fan must be properly grounded as a  
precaution against possible electrical  
shock.  
4. Connect one black wire of wall control  
to the “hot” wire. Securely connect  
wires with wire connectors supplied  
(Figure 7).  
5. Connect one black wire of wall switch  
to the “load” (black) wire in wall box.  
Securely connect wires with wire  
connector supplied.  
6. Screw wall control into wall box using  
1. Disconnect electrical power to the  
branch circuit at the circuit breaker or  
fuse box before attempting to install the  
ceiling fan wall control into the outlet box.  
the supplied screws.  
Leave wall  
control in “OFF” mode until fan  
installation is completed.  
!
WARNING  
!
WARNING  
Check to see that all connections are tight  
and that no bare wires are visible at the  
wire connectors.  
Do not connect any neutral (white) wire to  
this control. Incorrect wiring will damage  
this control.  
7. The wall control is supplied with a  
white, ivory, and almond color switch  
covers. Choose the finish that best  
suits your needs and snap the cover  
onto the wall control (Figure 7).  
2. At all wall box locations remove  
faceplates and screws from existing  
controls. Pull controls out from wall  
boxes and determine which wall box  
contains the “hot” lead and which wall  
box contains the “load” wire. Also,  
identify traveler wires which are  
common to both wall boxes.  
Disconnect wires from existing controls  
only. Do not attempt to disconnect any  
wires not already connected to existing  
controls.  
8. Install decorator wall plate (purchased  
separately) using the two screws  
provided with wall plate. Leave wall  
control in “OFF” mode until fan  
installation is completed (Figure 7).  
SCREWS (2)  
3. Before installing wall control, place wall  
control in “OFF” mode by pushing  
“ON/OFF” switch to the “OFF” position.  
K
L
B
HOT  
T
O
E
C
1
2
0
R
U
A
C
SO  
T
O
L
D
OA  
4. Install a wall control in the wall box  
containing the “hot” wire first. Connect  
the black wire of the wall control to the  
“hot” wire. Securely connect wires with  
wire connectors supplied.  
K
D
C
N
U
LA  
B
O
R
G
WALL  
BOX  
SWITCH  
COVER  
DECORATIVE  
WALL PLATE  
FAN/LIGHT  
WALL CONTROL  
5. Connect one black wire of the wall  
control to both remaining traveler wires  
in the wall box and secure with wire  
connector supplied.  
Figure 7  
NOTE: Retrofit 3-way installations are  
likely to include two traveler wires  
between the two wall boxes. In new  
construction, only one traveler wire Is  
required (See Figure 9).  
7
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 8  
3-WAY WIRlNG DIAGRAM:  
NEW CONSTRUCTION  
STANDARD WIRING FOR EXISTING  
3-WAY CONTROLS  
!
WARNING  
EXISTING  
WALL CONTROL  
HOT  
BLK  
Check to see that all connections are tight  
and that no bare wires are visible at the  
wire connectors.  
TRAVELER WIRES  
SW605  
LOAD  
HOT  
FAN/LIGHT  
3-WAY WIRING DIAGRAM: RETROFIT  
BLK  
WALL  
CONTROL  
N  
BLK  
BLACK  
BLK  
HOT BLK  
LOAD  
BLACK  
TRAVELER  
WIRE  
FF
GROUND  
NEUTRAL  
RECEIVER LOCATED  
WITHIN THE CEILING  
COVER  
FAN/LIGHT  
WALL CONTROL  
TRAVELER WIRES  
LOAD  
Figure 9  
Figure 8  
6. Screw wall control into wall box using  
the supplied screws. Leave wall  
Operation of Your Wall  
Control (Figure 10)  
control in “OFF” mode until fan  
installation is completed.  
7. The wall control is supplied with a  
white, ivory, and almond color switch  
covers. Choose the finish that best  
suits your needs and snap the cover  
onto the wall control (Figure 7).  
IMPORTANT  
Fan installation must be completed,  
including the installation of the fan  
blades, before testing the remote control.  
8. Next, install the other wall control into  
the wall box containing the load wire.  
Connect the black wire of the wall  
control to the traveler wire(s) already  
connected to the black wire (in the  
other wall box). Secure with wire  
connectors supplied.  
Your wall control has full control of your  
fan and light.  
NOTE: Prior to operation of the fan and  
light from the wall control, set the fan  
....  
speed to HIGH ( ) and turn the light  
ON (  
1. To set the desired fan speed, press the  
) button to decrease the speed and  
).  
9. Connect one black wire of the wall  
control to the “load” (black) wire and  
secure with wire connector supplied.  
(
the ( ) to increase the speed. The LED  
display will light up to indicate the new  
speed selected.  
2. To turn the light on and off, press and  
release the LIGHT (  
) button. To set  
the light intensity, press and hold the  
LIGHT ( ) button. The light will turn on  
at the light intensity previously selected.  
3. Your wall control comes complete with  
your choice of three wall cover plates;  
ivory, white and light almond.  
8
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 9  
4. If airflow is desired in the opposite  
direction, press the ( ) button on the  
CAPACITOR  
MOTOR  
SPEED  
wall control. The fan must be operating  
at any speed for the reverse button to  
function. The blades will turn in the  
opposite direction and reverse the  
airflow.  
CONTROL  
SWITCH  
CONNECTOR  
KNURLED  
NUT  
WIRING  
HARNESS  
CONNECTOR  
PULL  
POWER  
INDICATOR  
LIGHT  
CHAIN PLUG  
SCREW (2)  
REVERSING  
SWITCH  
SWITCH HOUSING  
LIGHT  
BUTTON  
Figure 11  
FAN  
DIRECTION  
NOTE: Keep the uplight switch if you  
think you may like to return to manual  
control in the future.  
HIGH TO LOW  
FAN  
BUTTON  
SPEED BUTTONS  
3. Remove two screws securing the  
reversing switch to the switch housing  
and place the pull chain plug in the  
exposed hole.(Figure 12).  
ON/OFF SWITCH  
O = OFF / — = ON  
SPEED CONTROL  
SWITCH  
Figure 10  
KNURLED  
NUT  
SECTION THREE:  
CEILING FAN  
PROCEDURES  
Installation to Operate the  
Ceiling Fan, Downlight  
and Uplight  
PULL  
REVERSING  
CHAIN PLUG  
SWITCH  
SWITCH HOUSING  
SCREW (2)  
Figure 12  
4. Remove the speed control switch and  
reversing switch capacitor. Position the  
RC188/RC212 module into the switch  
housing (Figure 13).  
IMPORTANT  
It is important that you also follow the  
installation instructions contained in  
the Owner’s Manual supplied with your  
Ceiling Fan. Pay particular attention to  
the Safety Instructions and WARNING  
notes.  
RC188/RC212 MODULE  
SWITCH HOUSING  
1. Remove and retain the screws  
securing the housing cover to the  
switch housing (Figure 11).  
PULL  
CHAIN  
PLUG  
2. All Ceiling Fan Models. Disconnect  
the motor connector from the wiring  
harness connector (Figure 11).  
Remove the knurled nut securing the  
speed control switch to the switch  
housing and place the pull chain plug in  
the exposed hole.  
Figure 13  
9
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 10  
TO 110V  
SUPPLY  
5. Connect the 6-pin wiring connector of  
LISTED GENERAL  
USE ON/OFF WALL  
SWITCH OR  
RECEIVER  
BLACK  
the module to the ceiling fan motor  
assembly wiring connector. The  
connectors are keyed and must be  
mated correctly before they can be  
engaged (Figure 14).  
SUPPLY  
WIRE  
OPTIONAL  
EMERSON SW605  
WALL CONTROL  
WHITE SUPPLY  
WIRE  
WHITE RECEIVER  
WIRE  
BLACK RECEIVER WIRE  
BLUE RECEIVER WIRE*  
BLACK/WHITE  
RECEIVER WIRE  
YELLOW RECEIVER  
WIRE**  
BLUE FAN WIRE  
WHITE FAN WIRE  
BLACK FAN WIRE  
6-PIN WIRING  
CONNECTOR  
FROM CEILINGFAN  
YELLOW FAN WIRE  
(FROM UPLIGHT)  
6-PIN WIRING  
MODULE CONNECTOR  
FROM SWITCH  
HOUSING  
YELLOW UPLIGHT WIRES  
DOWNROD  
(NOT PRESENT ON ALL FANS)  
RED AND BROWN  
WIRES - CAPPED.  
DO NOT REMOVE  
WIRE  
MOTOR COUPLING  
FAN HOUSING  
PULL CHAIN  
PLUG  
CONNECTORS  
OPTIONAL  
LIGHT FIXTURE  
Figure 14  
* IF YOUR CEILING FAN DOES NOT  
HAVE A DOWNLIGHT, CAP THE BLUE  
RECEIVER WIRE USING A WIRE  
CONNECTOR.  
** IF YOUR CEILING FAN DOES NOT  
HAVE AN UPLIGHT, THERE WILL BE  
NO YELLOW FAN WIRE.  
IN THIS CASE, CAP THE YELLOW  
RECEIVER WIRE USING A WIRE  
CONNECTOR.  
6. Assemble your ceiling fan (including  
the fan blades), install the hanger  
bracket, and then hang the fan in  
accordance with the instructions in the  
Ceiling Fan Owner’s Manual. Wire the  
ceiling fan and receiver and complete  
the installation in accordance with the  
following Steps 6 through 12.  
Figure 16  
9. Using wire connectors (supplied),  
make wiring connections as follows  
(Figure 15 and 16):  
a. Connect the green ground wires  
from the hanger bracket and the  
hanger ball to the supply ground  
wire (bare or green).  
7. Pull the wire leads, coming from the  
end of the downrod, and the supply  
wires through the open side of the  
hanger bracket. (Figure 15).  
b. Connect the white fan wire and the  
white supply wire to the white  
receiver wire (AC IN/MOTOR N).  
8. Position the RC188/RC212 Receiver in  
the ceiling cover so that the flat side of  
the receiver faces up and the open  
portion of the receiver is to the right, as  
shown in Figure 15.  
c. Connect the black fan wire to the  
black receiver wire (TO MOTOR  
L).  
OUTLET BOX  
BLACK SUPPLY WIRE  
BLACK FAN WIRE  
HANGER BRACKET  
HANGER BRACKET  
GROUND WIRE  
(GREEN)  
BLACK/WHITE RECEIVER WIRE  
BLUE FAN WIRE  
HANGER BALL  
GROUND WIRE  
(GREEN)  
BLUE RECEIVER  
WIRE  
OPEN PORTION  
OF RECEIVER  
HERE  
SUPPLY  
GROUND  
WIRE (GREEN  
OR BARE)  
YELLOW FAN WIRE  
YELLOW RECEIVER  
WIRE  
RECEIVER  
BLACK RECEIVER  
WIRE  
WHITE SUPPLY  
WIRE  
WHITE RECEIVER WIRE  
CEILING COVER  
WHITE FAN WIRE  
WIRE CONNECTOR  
Figure 15  
10  
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 11  
d. Connect the black supply wire to  
the black/white receiver wire (AC  
IN L).  
12. Slide the receiver up and over the  
hanger bracket. Press the receiver  
against the ceiling, holding it in place  
while installing the ceiling cover in  
accordance with the instructions in  
the Ceiling Fan Owner’s Manual.  
e. Cut off the end of the blue and  
yellow receiver wires and strip  
back insulation 1/2” from the end  
of the wires.  
13. Install the optional Emerson Light  
Fixture in accordance with the  
instructions in the Light Fixture  
Owner’s Manual. Use the screws  
removed in Step 1.  
f. Connect the blue fan wire to the  
blue receiver wire (BOTTOM  
LIGHT).  
g. Connect the yellow fan wire to the  
yellow receiver wire (UPPER  
LIGHT).  
NOTE: To prevent damage to the  
receiver, turn “off” the electricity at the  
wall switch before installing or  
removing light bulbs on the ceiling fan  
or light fixture.  
CAUTION: If your ceiling fan does NOT  
have an uplight, there will be NO yellow  
fan wire. In this case, cap the yellow  
receiver wire using a wire connector  
(supplied). If your ceiling fan does NOT  
have a downlight, cap the blue receiver  
wire using a wire connector (supplied).  
Trouble Shooting  
Fan/Light Fails to Operate  
10. nsert the connected ends of the wires  
up through the open side of the  
hanger bracket and into the outlet box  
as shown in Figure 17.  
Check that the speed switch on the  
....  
fan is set to HIGH ( ) speed.  
Check that the light switch is on.  
Check that the battery is good  
(red indicator light should light when  
any button is pressed).  
OUTLET BOX  
Check that the receiver is wired  
properly.  
HANGER  
BRACKET  
RECEIVER  
Check that code switches in the  
remote control and receiver are set in  
the same position.  
1-1/4"  
THREADED  
STUDS (2)  
CEILING  
COVER  
Short Range  
If the remote control operates the fan  
when close to it, but does not operate  
it at a distance of 40 feet, try placing  
the antenna wire outside of the ceiling  
cover.  
Figure 17  
11. Screw two 1-1/4” threaded studs  
(supplied with the ceiling fan) into the  
tapped holes in the hanger bracket  
(Figure 15).  
11  
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 12  
LIMITED WARRANTY  
What The Warranty Covers:  
All products covered by this Owner’s Manual are warranted against all defects in workmanship and materials.  
You must be the original purchaser or user of the product to be covered.  
What The Period Of Coverage Is:  
All components are covered by this warranty for one year from the date you purchased your Receiver ANY  
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH  
RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.  
What Will Emerson Electric Co. Do To Correct Problems:  
Emerson will replace a defective Emerson Receiver at no charge to you. We will ship the repaired product or  
replacement to you at no charge, but you are responsible for all costs or removal, reinstallation and  
shipping of the product to Emerson.  
How Can You Get Service:  
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE RECEIVER TO OBTAIN LIMITED WARRANTY SERVICE.  
KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your  
nearest authorized service center.  
To return the product to the factory, obtain a return authorization and service identification tag by writing to  
Air Comfort Products, Division of Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136.  
Include all model numbers shown on the product with your request.  
To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest  
authorized service center.  
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized  
service center. Your Emerson Receiver should be properly packed to avoid damage in transit since we will not  
be responsible for any such damage.  
What Is Not Covered:  
This warranty also does not cover any defects, malfunctions or failures caused by:  
Repairs by persons not authorized by Emerson Electric Co.,  
Use of parts or accessories not authorized by Emerson Electric Co.,  
Mishandling, improper installation, modifications or damage to your receiver while in your possession, or  
Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal  
wear and tear.  
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are  
voided when:  
The original purchaser or user ceases to own the product, or  
The ceiling fan is moved from its original point of installation.  
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other  
written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any  
warranties on behalf of Emerson Electric Co.  
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS  
WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL  
AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of  
time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing  
other property which was damaged if this product does not work properly.  
How State Law Relates To The Warranty:  
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above  
exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also  
have other rights which vary from state to state.  
Air Comfort Products  
DIVISION OF EMERSON ELECTRIC CO.  
8100 W. Florissant • St. Louis, MO 63136  
Part No. F40BP74150000  
Printed in China 10/09  
Form No. BP7415  

York Ycjd18 User Manual
Whirlpool Acq102 User Manual
Sanyo Uf103450p User Manual
Sanyo Twicell Hr Aau User Manual
Ricoh 350e User Manual
MAYTAG MGR8800F User Manual
MAKITA HP488D 02 User Manual
GARMIN ASUS NUVIFONE G60 User Manual
CRAFTSMAN 917.370921 User Manual
BLACK DECKER GT440 User Manual